-- MICROCHIP TECHNOLOGIES SNMP STACK SMIV2 SPECIFICATION DEMO CONTROL MIB -- ARBIT-MIB DEFINITIONS ::= BEGIN IMPORTS MODULE-IDENTITY,enterprises, IpAddress ,Integer32 FROM SNMPv2-SMI -- Gauge, TimeTicks FROM RFC1155-SMI DisplayString FROM SNMPv2-TC OBJECT-TYPE FROM RFC-1212 NOTIFICATION-TYPE FROM SNMPv2-SMI -- TRAP-TYPE FROM RFC-1215 SnmpSecurityModel, SnmpMessageProcessingModel, SnmpSecurityLevel, SnmpAdminString FROM SNMP-FRAMEWORK-MIB KeyChange FROM SNMP-USER-BASED-SM-MIB TEXTUAL-CONVENTION FROM SNMPv2-TC MODULE-COMPLIANCE, OBJECT-GROUP , NOTIFICATION-GROUP FROM SNMPv2-CONF; ArbitInfo MODULE-IDENTITY LAST-UPDATED "201106080000Z" ORGANIZATION "Arbit Ingeniería" CONTACT-INFO "www.arbitingeniería" DESCRIPTION "The MIB for SNMP agent ETE_v1." REVISION "201528030000Z" DESCRIPTION "The MIB module for ETE_v1." ::= { Arbit_Ingenieria 1 } Arbit_Ingenieria OBJECT IDENTIFIER ::= { enterprises 17095 } product OBJECT IDENTIFIER ::= { ArbitInfo 1 } setup OBJECT IDENTIFIER ::= { ArbitInfo 2 } control OBJECT IDENTIFIER ::= { ArbitInfo 3 } snmpUsm OBJECT IDENTIFIER ::= { ArbitInfo 4 } snmpTrap OBJECT IDENTIFIER ::= { ArbitInfo 5 } snmpv3PvtObject OBJECT IDENTIFIER ::= { ArbitInfo 6 } trapNotifications OBJECT IDENTIFIER ::= { ArbitInfo 0 } mchipMIBConformance OBJECT IDENTIFIER ::= { ArbitInfo 8 } mchipMIBCompliances OBJECT IDENTIFIER ::= { mchipMIBConformance 1 } mchipMIBGroups OBJECT IDENTIFIER ::= { mchipMIBConformance 2 } -- ON-OFF ::= INTEGER { ON(1), OFF(0) } MCHPUsmAuthPrivProtocol ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "This textual convention enumerates the authentication and privledge protocol for USM configuration. " SYNTAX INTEGER { noAuthProtocol(1), hmacMD5Auth(2), hmacSHAAuth(3), noPrivProtocol(4), desPrivProtocol(5), aesPrivProtocol(6) } Nombre_Nodo OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Controlador ETE v1" ::= { product 1 } version OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Version 1.0" ::= { product 2 } date OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "2015 28 03 " ::= { product 3 } Salida1 OBJECT-TYPE SYNTAX INTEGER { off(0), on(1) } MAX-ACCESS read-write STATUS current DESCRIPTION "Salida 1 connected LATA2" ::= { control 1 } Salida2 OBJECT-TYPE SYNTAX INTEGER { off(0), on(1) } MAX-ACCESS read-write STATUS current DESCRIPTION "Salida 2 connected to LATA3" ::= { control 2 } Salida3 OBJECT-TYPE SYNTAX INTEGER { off(0), on(1) } MAX-ACCESS read-write STATUS current DESCRIPTION "Salida 3 connected to LATA3" ::= { control 3 } Salida4 OBJECT-TYPE SYNTAX INTEGER { off(0), on(1) } MAX-ACCESS read-write STATUS current DESCRIPTION "Salida 3 connected to LATA3" ::= { control 4 } Entrada1 OBJECT-TYPE SYNTAX INTEGER { closed(0),open(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "Entrada Digital 1" ::= { control 5 } Entrada2 OBJECT-TYPE SYNTAX INTEGER { closed(0),open(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "Entrada Digital 2" ::= { control 6 } Entrada3 OBJECT-TYPE SYNTAX INTEGER { closed(0),open(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "Entrada Digital 3" ::= { control 7 } Entrada4 OBJECT-TYPE SYNTAX INTEGER { closed(0),open(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "Entrada Digital 4" ::= { control 8 } analog0-10v OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "10-bit A/D value" ::= { control 9 } analog4-20mA OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "10-bit A/D value" ::= { control 10 } analogBat OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "10-bit A/D value" ::= { control 11 } analogTemp OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "10-bit A/D value" ::= { control 12 } statusPLC OBJECT-TYPE SYNTAX INTEGER { off(0), on(1) } MAX-ACCESS read-write STATUS current DESCRIPTION "Habilitacion de la rutina PLC" ::= { control 13 } trapTable OBJECT-TYPE SYNTAX SEQUENCE OF TrapEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Trap table" ::= { setup 1 } trapEntry OBJECT-TYPE SYNTAX TrapEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Single trap entry containing trap receiver info." INDEX { trapReceiverNumber } ::= { trapTable 1 } TrapEntry ::= SEQUENCE { trapReceiverNumber Integer32, trapEnabled Integer32, trapReceiverIPAddress IpAddress, trapCommunity DisplayString } trapReceiverNumber OBJECT-TYPE SYNTAX Integer32(0.. 4) MAX-ACCESS not-accessible STATUS current DESCRIPTION "Index of trap receiver" ::= { trapEntry 1 } trapEnabled OBJECT-TYPE SYNTAX INTEGER { no(0),yes(1) } MAX-ACCESS read-write STATUS current DESCRIPTION "Indicates if this trap entry is enabled or not." ::= { trapEntry 2 } trapReceiverIPAddress OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-write STATUS current DESCRIPTION "Trap receiver IP address" ::= { trapEntry 3 } trapCommunity OBJECT-TYPE SYNTAX DisplayString (SIZE (0..7)) MAX-ACCESS read-write STATUS current DESCRIPTION "Trap community to be used by agent to send trap" ::= { trapEntry 4 } mchpUsmUserTable OBJECT-TYPE SYNTAX SEQUENCE OF MchpUsmUserEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table is used to configure microchip USM. To get the SNMPv3 access, user need to configure security name,authentication,auth password,priv protocol and priv password. " ::= { snmpUsm 1 } mchpUsmUserEntry OBJECT-TYPE SYNTAX MchpUsmUserEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "User security configurations for USM. " INDEX { usmIndex } ::= { mchpUsmUserTable 1 } MchpUsmUserEntry ::= SEQUENCE { usmIndex Integer32, usmSecurityName SnmpAdminString, usmAuthProtocol MCHPUsmAuthPrivProtocol, usmAuthKey KeyChange, usmPrivProtocol MCHPUsmAuthPrivProtocol, usmPrivKey KeyChange } usmIndex OBJECT-TYPE SYNTAX Integer32 (1..3) MAX-ACCESS not-accessible STATUS current DESCRIPTION "Usm configuration index. " ::= { mchpUsmUserEntry 1 } usmSecurityName OBJECT-TYPE SYNTAX SnmpAdminString MAX-ACCESS read-write STATUS current DESCRIPTION "A human readable string representing the user in Security Model independent format. The default transformation of the User-based Security Model dependent security ID to the securityName and vice versa is the identity function so that the securityName is the same as the userName. " ::= { mchpUsmUserEntry 2 } usmAuthProtocol OBJECT-TYPE SYNTAX MCHPUsmAuthPrivProtocol MAX-ACCESS read-write STATUS current DESCRIPTION "Authentication support to the SNMPv3. If usmAuthProtocol == NoAuthProtocol, then SNMPv3 Stack does not support/requires authentication. If usmAuthProtocol == HMACMD5Auth , supports MD5 auth If usmAuthProtocol == HMACSHAAuth, supports SHA Auth If a set operation tries to set value as NoAuthProtocol while the usmPrivProtocol value for the same userName is not equal to NoPrivProtocol, then an 'inconsistentValue' error must be returned. This implies that SNMP command generator (SNMP Manager) application must first ensure that the usmPrivProtocol is set to NoPrivProtocol value before it can set the usmAuthProtocol value to NoAuthProtocol. " ::= { mchpUsmUserEntry 3 } usmAuthKey OBJECT-TYPE SYNTAX KeyChange -- typically (SIZE (0 | 32)) for HMACMD5 -- typically (SIZE (0 | 40)) for HMACSHA MAX-ACCESS read-write STATUS current DESCRIPTION "This object in the MIB is associated to usmAuthProtocol. A secret authentication key is required to establish a secure connection between snmp agent and manager. " ::= { mchpUsmUserEntry 4 } usmPrivProtocol OBJECT-TYPE SYNTAX MCHPUsmAuthPrivProtocol MAX-ACCESS read-write STATUS current DESCRIPTION " A privacy protocol to provide encryption and decryption of SNMPv3 pdu. " ::= { mchpUsmUserEntry 5 } usmPrivKey OBJECT-TYPE SYNTAX KeyChange -- typically (SIZE (0 | 32)) for DES MAX-ACCESS read-write STATUS current DESCRIPTION "This object in the MIB is associated to usmPrivProtocol. A secret privacy key is required to establish a secure connection between snmp agent and manager. " ::= { mchpUsmUserEntry 6 } -- Target MIB mchpTargetTable OBJECT-TYPE SYNTAX SEQUENCE OF MchpTargetEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A table for SNMP target information. This information is required for generation of SNMP trap notifications." ::= { snmpTrap 1 } mchpTargetEntry OBJECT-TYPE SYNTAX MchpTargetEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A set of SNMP target information. " INDEX { snmpTargetIndex } ::= { mchpTargetTable 1 } MchpTargetEntry ::= SEQUENCE { snmpTargetIndex Integer32, snmpTargetMPModel SnmpMessageProcessingModel, snmpTargetSecurityModel SnmpSecurityModel, snmpTargetSecurityName SnmpAdminString, snmpTargetSecurityLevel SnmpSecurityLevel } snmpTargetIndex OBJECT-TYPE SYNTAX Integer32(1..8) MAX-ACCESS not-accessible STATUS current DESCRIPTION "The locally arbitrary, but unique identifier associated with mchpTargetEntry." ::= { mchpTargetEntry 1 } snmpTargetMPModel OBJECT-TYPE SYNTAX SnmpMessageProcessingModel MAX-ACCESS read-write STATUS current DESCRIPTION "The Message Processing Model to be used when generating/processing SNMP messages using this entry." ::= { mchpTargetEntry 2 } snmpTargetSecurityModel OBJECT-TYPE SYNTAX SnmpSecurityModel (1..2147483647) MAX-ACCESS read-write STATUS current DESCRIPTION "The Security Model to be used while generating SNMP messages using this entry. An implementation may choose to return an inconsistentValue error if an attempt is made to set this variable to a value for a security model which the implementation does not support." ::= { mchpTargetEntry 3 } snmpTargetSecurityName OBJECT-TYPE SYNTAX SnmpAdminString MAX-ACCESS read-write STATUS current DESCRIPTION "The securityName which identifies the Principal on whose behalf SNMP messages will be generated. " ::= { mchpTargetEntry 4 } snmpTargetSecurityLevel OBJECT-TYPE SYNTAX SnmpSecurityLevel MAX-ACCESS read-write STATUS current DESCRIPTION "The Level of Security to be used when generating SNMP messages using this entry." ::= { mchpTargetEntry 5 } snmp-demo-trap NOTIFICATION-TYPE OBJECTS { analogPot0,pushButton,ledD5,trapCommunity} STATUS current DESCRIPTION "SMIV2 Trap notification information for the SNMP Manager. The objects used in the demo trap notification are analogPot0,pushButton,ledD5 and trapCommunity. User should modify this object information as per the requirements. These object should have been defined as part of the MIB. " ::= {trapNotifications 1} mchipDemoCompliance1 MODULE-COMPLIANCE STATUS current DESCRIPTION "This group is for SNMP demo applications." MODULE -- this module MANDATORY-GROUPS { mchipDemoGroup1, mchipDemoGroup2} ::= { mchipMIBCompliances 1 } mchipDemoCompliance2 MODULE-COMPLIANCE STATUS current DESCRIPTION "This group is for trap demo applications." MODULE -- this module MANDATORY-GROUPS {mchipDemoGroup3} ::= { mchipMIBCompliances 2 } mchipDemoGroup1 OBJECT-GROUP OBJECTS { name, version,date,Entrada1,Entrada2,Entrada3,Entrada4,Salida1,Salida2,Salida3,Salida4, analogPot0,analogBat,analogTemp, trapEnabled,trapReceiverIPAddress,trapCommunity} STATUS current DESCRIPTION "A collection of objects providing basic product and control of a product." ::= { mchipMIBGroups 1 } mchipDemoGroup2 OBJECT-GROUP OBJECTS { usmSecurityName,usmAuthProtocol,usmAuthKey, usmPrivProtocol,usmPrivKey,snmpTargetMPModel, snmpTargetSecurityModel,snmpTargetSecurityName, snmpTargetSecurityLevel} STATUS current DESCRIPTION "A collection of objects are used for SNMPV3 Configuration." ::= { mchipMIBGroups 2 } mchipDemoGroup3 NOTIFICATION-GROUP NOTIFICATIONS {snmp-demo-trap} STATUS current DESCRIPTION "SNMP Trap Notification object." ::= { mchipMIBGroups 3 } END